HOLLOW FIBER · MF / UF
Food process water and reuse
Where will the reclaimed water be used?

Evaluation candidate
Filtration and separation
Separate raw-water pretreatment, process water and treated effluent. Distinguish submerged MBR for wastewater from additional membrane treatment for proposed reuse.
What a trial can verify
Assess solids and turbidity control and the need for downstream treatment.
Review points and limits
Confirm the intended use, water variability, restricted constituents and applicable requirements. Membrane filtration or MBR alone does not establish suitability for product contact.
Define where reclaimed water will go before choosing a treatment step
- The problem on site
- Clear effluent may still contain salts, low-molecular-weight substances or microbial loads that matter at the destination. Mixing raw-water pretreatment with process and reuse targets risks unnecessary treatment and duplicated replacement.
- Proposed solution
- Start with whether the use contacts the product and whether it is cooling, washing or another duty. Assess biological treatment and submerged MBR for effluent separately from downstream MF or UF and any further treatment, against end-use quality and operating burden.
- What to verify before selection
- Document quality targets per use point, seasonal and cleaning-cycle variation, restricted constituents and monitoring. Confirm reuse and product-contact suitability against applicable requirements and site evidence rather than relying on a membrane step alone.