Filter Integrity Testing

Review filter integrity testers for sterile filtration, PUPSIT and gas or vent filters. Match supported methods, connections and records to filter-specific validated criteria.

Review selection pointsDiscuss this application
TEST APPLICATIONS

Which filters will be tested?

Liquid sterilizing filtration

Review pre-use and post-use test conditions for hydrophilic membranes and capsules.

Gas and vent filtration

Confirm test methods for hydrophobic filters, and housing, condensation and sterilization conditions.

PUPSIT configuration

Review connections, exhaust, recovery and records for pre-use post-sterilization testing.

FIELD APPLICATION & FLOW

See the application in its industrial setting.

Review product locations and fluid paths.

APPLICATION IN CONTEXT
Field example of a diffusion-flow test. Example test station connects gas, instrument, filter and records. Wetted liquid filters and hydrophobic gas filters use different preparation and validated methods. 1. Test-gas supply; 2. Automated integrity tester; 3. Filter under test; 4. Downstream boundary/exhaust; 5. Test record
Field example of a diffusion-flow test. Example test station connects gas, instrument, filter and records. Wetted liquid filters and hydrophobic gas filters use different preparation and validated methods.
  1. Test-gas supply
  2. Automated integrity tester
  3. Filter under test
  4. Downstream boundary/exhaust
  5. Test record

Connections to review

  • 01 → 02 Test-gas supply → Automated integrity tester
  • 02 → 03 Automated integrity tester → Filter under test
  • 03 → 04 Method-specific downstream path
  • 02 → 05 Automated integrity tester → Test record

Diffusion, bubble point, pressure hold and water intrusion use different setups and principles. Apply the validated filter-specific method. Review the method-specific connections and principles below for bubble point, pressure hold and water intrusion.

A conceptual illustration created to explain equipment and application locations. It is not an actual product photograph, installation photograph or piping/wiring design.

Connection principles and operating/test methods

2D PROCESS GUIDE

Diffusion flow · defined differential pressure

GasMeasurement / control
Automatic filter integrity tester — dimensional product illustration
PRODUCT TYPEAutomatic filter integrity testerIllustrative product form
Diffusion flow · defined differential pressureTest gas → Automated tester (Gas); Automated tester → Wetted filter (Gas); Wetted filter → Downstream side (Gas); Automated tester → Test record (Measurement / control). Evaluate gas diffusion through a wetted membrane at a validated differential pressure below its bubble point. Depending on the instrument, flow is measured directly or calculated from upstream volume and pressure change. Confirm filter-specific fluid, gas, temperature, area, limits and the downstream boundary.Test valuesTest gasQuality / pressureAutomated testerFlow / pressureWetted filterValidated fluidDownstream sideApproved boundaryTest recordIdentity / limits

Scroll horizontally to see the complete flow.

Evaluate gas diffusion through a wetted membrane at a validated differential pressure below its bubble point. Depending on the instrument, flow is measured directly or calculated from upstream volume and pressure change. Confirm filter-specific fluid, gas, temperature, area, limits and the downstream boundary.

These conceptual views explain flow direction. Actual piping, wiring and physical flow rates require a separate design.

01 — PROCESS

Where does each step fit?

Define the intended use and conditions to identify the required role of each item.

01

Filter and test preparation

Confirm the test object, whether the membrane is hydrophilic or hydrophobic, test fluid and gas, and sterilization history.

02

Connection and automated testing

Connect, wet and stabilize according to the approved procedure, then measure using the program for the relevant filter.

03

Assessment and records

Check acceptance limits, raw data, filter and batch identification, and operating history; investigate failures using the defined procedure.

02 — SELECTION

Which integrity-test method applies?

Automated integrity testers measure changes in gas flow or pressure and compare them with the validated criteria for the relevant filter. Review equipment according to filter type, test method, connection configuration and record requirements.

Scroll horizontally to review all columns.

Test methodEnglish designationPrinciple and conditions
Diffusion flow testDiffusion / Forward FlowMeasure gas flow when a specified differential pressure is applied to a wetted filter. Confirm the test fluid, area, gas, temperature and acceptance limit for the relevant filter.
Bubble point testBubble PointDetect the pressure at which wetting fluid is displaced from the membrane’s larger pores and gas flow increases. Confirm the wetting condition and validated method for each filter.
Pressure hold or decay testPressure Hold / DecayEvaluate pressure changes in the sealed upstream side. Confirm upstream volume, system leakage, temperature and the filter-specific correlation criteria.
Water intrusion testWater Intrusion Test · WITUse water to test suitable hydrophobic gas or vent filters. Confirm the filter, area, housing and scope of applicability of the validated method.

Use acceptance limits validated for the specific filter, test fluid, gas, temperature, area and actual configuration. Instruments differ in supported methods and features.

03 — OPERATING CHECKS

Confirm these points before selection.

Match test functions and operating range

Confirm the required test methods, filter area and number of filters, test volume, pressure and flow ranges, and measurement performance. Not every instrument supports every test method.

Review the process connections together

Check test-gas quality, filter connections, protection against liquid backflow and exhaust paths. PUPSIT requires a configuration that maintains the sterile boundary during post-sterilization testing.

Define records and maintenance

Define requirements for user permissions, audit trails, electronic signatures and result export. Review calibration, IQ/OQ and system qualification documentation.

04 — QUESTIONS

Frequently asked questions

Does a passing result guarantee product sterility?

The test evaluates filter and assembly condition under validated conditions. It does not replace validation of microbial retention, hygiene and sterility controls across the entire process, or product quality evaluation.

Should the filter be replaced immediately after a failed test?

Insufficient wetting, connection leaks, temperature changes and incorrect settings can also cause failure. Preserve the initial result and make the decision according to approved investigation and retest procedures.

Can this instrument also perform single-use bag leak tests?

Filter-test functions alone do not establish the ability to test bags for leakage. Separate supported functions, accessories, a validated method and the bag’s pressure limits are required.

Can existing filter test settings be copied to a new tester?

Use existing settings as comparison data, then confirm supported methods, units, measurement ranges and connections. Establish the validated criteria for the filter, area, test fluid, gas and temperature, together with the approved procedure and equipment qualification scope, before configuring the test program.

05 — APPLICATION REVIEW

Prepare the conditions for a technical discussion.

Share the current configuration and operating conditions to review selection criteria and required evidence. Suitability and supply scope are confirmed for each application.

Prepare an enquiry

Review your filtration requirements

Selection, replacement or quantity and lead-time review. Start with the information you have.

Review a replacement

Material, connection and sterilization requirements

Select for a new process

Application conditions and required documents

Request quantity & lead-time pricing

Known quantity, accessories and timing