Instantaneous flow, totalized volume & process signals

Single-use ultrasonic flowmeter

Combine a disposable inline detector with a reusable converter to measure instantaneous flow and totalized volume in biopharma liquid processes. Review the actual flow, bubbles and tubing conditions for filtration, buffer and media preparation, or liquid transfer.

Check liquid compatibility with the PSU wetted path, sound speed, kinematic viscosity, full-pipe conditions and entrained bubbles. Interpret accuracy against water calibration and the applicable velocity range; assess process qualification and electronic-record requirements separately.

Request a review or quotation
Single-use ultrasonic flowmeter — equipment form illustration
An illustration based on the equipment form, not a photograph of supplied equipment or an installation drawing.

Read the solution guide

QUESTIONS THAT CHANGE THE SELECTION

Read the specification
in your operating conditions.

01

Start with the flow you run most often.

Check where minimum and normal flow sit within the accuracy bands, alongside maximum capacity. Model-specific absolute errors apply at low velocity; do not interpret the entire range as ±1%.

02

A hose size does not define the measuring bore.

Different measuring bores and flow ranges can share a barb connection size. Review the connection, pressure loss, tubing stress, full-pipe conditions and drainage together.

03

Connect totalization to a usable record.

Define whether to record instantaneous flow or totalized volume, who may reset totals and when, and the required PLC signals or communication. Converter outputs alone do not establish electronic-record compliance.

APPLICATION CONTEXT

Where will the measurement be used?

The illustration below shows an example process context for sampling and sensors. Review instrument location, a full flow path and drainability, pressure loss, cable routing and controls against the actual piping or tubing assembly.

APPLICATION IN CONTEXT
Sensors and a sampling branch are shown on a closed process vessel: signals go to the controller, while sample liquid goes to a separate collection container. 1. Process vessel; 2. Process sensor; 3. Closed sampling; 4. Analysis area; 5. Control/record
Sensors and a sampling branch are shown on a closed process vessel: signals go to the controller, while sample liquid goes to a separate collection container.
  1. Process vessel
  2. Process sensor
  3. Closed sampling
  4. Analysis area
  5. Control/record

Sample-liquid paths and sensor signals are distinct. Record measurement location, calibration, sampling time and analysis delay.

A conceptual illustration created to explain equipment and application locations. It is not an actual product photograph, installation photograph or piping/wiring design.

DATA & ELECTRONIC RECORDS

Review the measurement signal
and the electronic record.

The reviewed catalogs do not establish compliance with 21 CFR Part 11 or document electronic-record and electronic-signature controls. Analog outputs or a communications connection do not establish compliance. Review electronic-record requirements against the connected system and intended use.

Define the record

Establish whether the readings are process indicators or electronic batch records subject to regulatory recordkeeping requirements.

Review system controls

Review access, timestamps, change history/audit trails, retention, retrieval and record-copy functions in the acquisition and storage system.

Verify intended use

Review validation evidence, operating procedures and responsibilities for the intended use, including electronic-signature requirements when signatures are used.

Determine Part 11 applicability from how records required under FDA regulations are used electronically. Assess instrument documentation and the record system’s controls and validation evidence separately.

Review references: FDA · Part 11 Scope and Application21 CFR 11.10

PREPARE YOUR APPLICATION REVIEW

Start the review
with your operating conditions.

  1. 01Define actual operating flows
  2. 02Compare detector and flow-path conditions
  3. 03Review signals and calibration evidence
  4. 04Confirm installation and recording requirements
Enquire about this product and duty

Other measurement methods and process guides

INSTALLATION CONTEXT

Inline measurement on a transfer line

A clear measuring section between process tubing runs, with its leads routed to an instrument
Inline measurement on a transfer line

Illustrations show typical installation contexts, not product photos or drawings. Confirm connections and dimensions against the selected equipment's documentation.

A good water reading is not evidence at your lowest batch flow

Relevant manufacturer: TOKYO KEISO CO., LTD.

The problem on site
Air during start-up or a partially filled path can make an actual batch differ from a water-based check. Low conductivity alone also does not establish suitability for every ultrasonic configuration.
Proposed solution
Review the reusable converter and replaceable inline ultrasonic sensor as a pair. Separate instantaneous readings from accumulated volume, and compare low and normal flow using the actual liquid, tubing and orientation.
What to verify before selection
Check fluid properties, bubbles/full-pipe conditions, connections, working flow range, output and total reset. Assess accuracy and suitability against the selected configuration.

Next stepCompare measurement methods and operating conditions